Как обнулить показания электроэнергии в Tasmota

Для сброса или установки показаний в Tasmota можно использовать команды в консоли

EnergyResetпоказать значения Energy Total, Yesterday and Today
EnergyReset10..42500((P)Re)Set Energy Today in Wh
EnergyReset20..42500((P)Re)Set Energy Yesterday in Wh
EnergyReset30..42500000((P)Re)Set Energy Total in Wh
EnergyReset4<standard>{,<off-peak>} ((P)re)set tariff period values for Totals
EnergyReset5<standard>{,<off-peak>} ((P)re)set tariff period values for Exported

Работа с тарифами

Tariff<x>P1 Smart Meter tariff configuration
x = 1, 2, 9
1 STD,DST Start times for off-peak tariff
2 STD,DST End times for off-peak tariff
9 0/1
0 = use Start/End times also on weekends.
1 = use off-peak tariff all weekend.
STD and DST may be specified as:
<hour> = 0..23 or
<time> = 00:00..23:59 or
<minutes> = 0..1439 (since midnight)
If both Tariff1 STD and Tariff2 STD are equal, all tariffs are disabled.

в старших версиях  > 10.x Tasmota эти параметры заменены на

EnergyToday<x>Reset Energy Today values
0 = reset
<value> = set value
<time> = 0..4294967295 set StartTotalTime time as epoch value (optional 2nd parameter)
EnergyTotal<x>Reset Energy Total values
0 = reset
<value> = set value
<time> = 0..4294967295 set StartTotalTime time as epoch value (optional 2nd parameter)
The new value represents start of day, and output for total includes the today value.
EnergyYesterday<x>Reset Energy Yesterday values
0 = reset
<value> = set value
<time> = 0..4294967295 set StartTotalTime time as epoch value (optional 2nd parameter)